Comparison of bone loss around implants using radiographs

  • Shibi Mathew V Department of Prosthodontics, Pushpagiri College of Dental Sciences, Kerala, India
  • Aby Mathew T Department of Prosthodontics, Pushpagiri College of Dental Sciences, Kerala, India
  • Navin Oommen Thomas Department of Orthodontics, Pushpagiri College of Dental Sciences, Kerala, India
  • Joshy P. Abraham Department of Prosthodontics, Pushpagiri College of Dental Sciences, Kerala, India
  • Miranda George Department of Pedodontics, Pushpagiri College of Dental Sciences, Kerala, India
  • Nazia Rasheed Private Practitioner, Kerala, India
Keywords: dental implant, marginal bone loss, cone beam computed topography, radiovisiography, radiographic evaluation

Abstract

This article presents an original-research conducted at Pushpagiri College of Dental sciences, Thiruvalla, Kerala to compare and evaluate the vertical crestal bone changes around implants with different surface coatings and diame-ter using CBCT and RVG taken at the time of loading and one year after loading. Thirty-six samples were divided in 4 group; based on 3 parameters: implant surface coating, implant diameter, and single versus multiple implants sup-ported bridges. Length of all implants is kept standardised at 10 mm. Data were statistically analyzed by Students paired t-test and comparison between CBCT and RVG is done using interclass correlation test. The mean crestal bone loss has increased statistically significant from the time of loading and after one year of loading. The average crestal bone loss on single implants were less compared to multiple implants supported bridges at both timings. CBCT shows more accurate and reliable values than RVG both clinically and statistically. It was concluded that crestal bone loss was less among single implants with calcium phosphate surface coating and wider diameter than alumina blasted and narrow diameter implants. Single implant shows less bone loss than multiple implants. The CBCT shows a reliable method of detecting circumferential peri-implant bone defects than RVG.

References

Ramakrishna R, Nayar S. Clinical assessment of primary stability of endosseous implants placed in the incisor region, using resonance frequency analysis methodology: an in-vivo study. Indian J Dent Res Publ Indian Soc Dent Res 2007;18(4):168-72.

Chung DM, Oh T-J, Lee J, Misch CE, Wang H-L. Factors affecting late implant bone loss: a retrospective ana-lysis. Int J Oral Maxillofac Implants 2007;22(1):117-26.

Verhoeven JW, Cune MS, de Putter C. Reliability of some clinical parameters of evaluation in implant dentistry. J Oral Rehabil 2000; 27(3):211-6.

Albrektsson A. The longterm efficacy of currently used dental implants: A review and proposed criteria of suc-cess. Int J Oral Maxillofac Implants [Internet]. [cited 2017 Nov 8];1986(1):11-25.

Oh TJ, Misch CE, Lau K. The causes of early implant bone loss: Myth or Science? 2002; 73: 322.

Leonardo MR, Borges ATN, Martins-Junior W, de Queiroz AM, Assed S. Vertical alveolar crest bone mainte-nance around implants in two-stage surgery: an in-situ study in dogs. Braz Dent J 2008;19(2):103-8.

van Steenberghe D, Naert I, Jacobs R, Quirynen M. Influence of inflammatory reactions vs occlusal loading on peri-implant marginal bone level. Adv Dent Res [internet].1999 [cited 2017 Nov 20];13(1):130-5.

Himmlova L, Dostalova T, Kacovsky A, Konvickova S. Influence of implant length and diameter on stress distri-bution: a finite element analysis. J Prosthet Dent 2004;91(1):20-5.

Vikhe DM, Tambe SD, Mascarenhas R, Bawane S, Jadhav R, Kathariya R. Assessment of crestal bone loss surrounding the implant before prosthetic loading of dental implant systems: A pilot study. J Int Oral Health 2016; 8(12):1110-3.

Jung YC, Han CH, Lee KW. A 1-year radiographic evaluation of marginal bone around dental implants. Int J Oral Maxillofac Implants1996;11(6):811-8.

Roccuzzo M, Bunino M, Prioglio F, Bianchi SD. Early loading of sandblasted and acid-etched (SLA) implants: a prospective split-mouth comparative study. Clin Oral Implants Res 2001;12(6):572-8.

Misch CE. Implant success or failure: Clinical assessment in implant dentistry. In: Contemp Implant Dent. St. Louis: Mosby; 1993. p.33-66.

Rajpal J, Srivastava A, Tandon P, Chandra C, Gupta K. Assessment of hard and soft tissue changes around im-plants: A clinic-radiographic in-vivo study. J Dent Implants [Internet].2014[cited 2017 Nov 20];4(2):126.

Jimbo R, Ancheita R, Baldassarri M, Granato R, Marin C, Teixaira HS, et al. Histomorphometry and bone me-chanical property evolution around different implant systems at early healing stages: an experimental study in dogs. Implant Dent 2013;22(6):596-603.

Singh P, Garge HG, Parmar VS, Viswambaran M, Goswami MM. Evaluation of implant stability and crestal bone loss around the implant prior to prosthetic loading: A six-month study. J Indian Prosthodont Soc 2006:6(1):33.

Ding X, Liao SH, Zhu XH, Zhang XH, Zhang L. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants. Clin Implant Dent Relat Res 2009;11(4):279-87.

Strong JT, Misch CE, Bidez MW, Nalluri P. Functional surface area: thread-form parameter optimization for im-plant body design. Compend Contin Educ Dent 1998;19(3):4-9.

Scurria MS, Shugars DA, Hayden WJ, Felton DA. General dentist patterns of restoring: endodontically treated teeth. J Am Dent Assoc 1995;126(6):775-9.

Ghahroudi AR, Talaeppour AR, Mesgarzadeh A, Rokn A, Khorsand A, Mesgarzadeh N, et al. Radiographic vertical bone loss evaluation around dental implants following one year of functional loading. J Dent Tehran Univ Med Sci [Internet].2010 [cited 2017 Nov 9]:7(2):89-97.

Norton MR. Biologic and mechanical stability of single-tooth implants: 4-7 years follow -up. Clin Implant Dent Relat Res 2001;3(4):214-20.

Norton MR. Multiple single-tooth implant restorations in the posterior jaws: maintenance of marginal bone levels with reference to the implant abutment microgap. Int J Oral Maxillofac Implants 2006;21(5).

Gotfredsen K. A 5-year prospective study of single tooth replacements supported by the Astra Tech implant: A pilot study. Clin Implant Dent Relat Res 2004;6(1):1-8.

Guichet DL, Yoshinobu D, Caputo AA. Effect of splinting and interproximal contact tightness on load transfer by implant restorations. J Prosthet Dent 2002;87(5):528-35.

Kwon MJ, Yeo IS, Kim YK, Yi YJ, Yang JH. Use of separate single tooth implant restorations to replace two or more consecutive posterior teeth: a prospective cohort study for up to 1 year. J Adv Prosthodont 2010;2(2):54-7

Yepes JF, Al-Sabbagh M. Use of cone-beam computed tomography in early detection of implant failure. Dent Clin [Internet]. 2015 [cited 2017 Nov16];59(1):41-56.

Akdeniz BG, Oksan T, Kovanlikaya I, Genc I. Evaluation of bone height and bone density by computed tomo-graphy and panoramic radiography for implant recipient sites. J Oral Implantol 2000;26(2):114-9.

Raes F, Cosyn J, Crommelinck E, Coessens P, de Bruyn H. Immediate and conventional single implant treat-ment in the anterior maxilla: 1-year results of a case series on hard and soft tissue response and esthetics. J Clin Periodontol 2011;38(4):385-94.

Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981:10(6):387-416.

Published
2022-06-01
Section
Articles